Product Detail :
|
Supply of floor mounted Dx-type double skinned AHU made from 0.6mm GSS prepainted outer sheet and 0.6mm plain GSS inner sheet in between 50mm thick, 40kg/m3 density PUF insulation. AHU comprising of Pre filter section, coil section with suitable 6 RD DX cooling coil with Aluminium fins, fan section with DIDW backward curved with 130 mm static pressure and standard TEFC Sq. cage induction motor with drive package of suitable capacity along with Supply Air GI dampers. (U trap ready made MS Galvanised ). Prefilters down to 10 microns filteration. (The AHU shall be outdoor type to withstand ambient condition).Location - CFM - TR - TSP in mm , Supply of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating having all hermetically sealed inverter type Scroll Compressor, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators etc complete as required. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. , Supply of Refnet of required size, AHU Connection Kit consisiting of for the operation of refrigerant circuits through Electronic Expansion Valve and control box., Installation, Testing and Commissiong of Air handling units 2500 CFM with AHU Kit, Installation, Testing and Commissiong of of 08 HP VRV Condensing units, Installation, Testing and Commissiong of of Refnet Joint., Suppyl, installation, Testing & Commisioning of refrigerant piping for suction & liquid line between indoor & outdoor units duly insulated by nitrile rubber insulation and exposed pipe covered with antiabrasive and UV protection coating/foil as per specifications. , Necessary Refrigerant Gas and oil charge for topping up the system/circuit for setting desired operating parameters., Fabricated Stand of MS base frame/platform for outdoor units complete with painting, vibration isolation pads, supports, hangers, railing, brackets etc. , Providing and Fixing in position the following UPVC pipes cut to required lengths and necessary fittings with 9mm thick closed cell elastomeric nitrile rubber insulation, Supply delivery Installation & testing Sheet Aluminium Ducting 22 Gauge TDF Flange turning vanes, with proper duct sealing etc complete as per technical specification., Supply, fabrication and installation of fire resistant flexible canvas sleeve flexible connections, Supply and installation manual fire damper with fusible link, Supply and installation Volume Control Damper, Return Air Aluminium Grill, Laminar Air Flow, Pressure Monitoring System, Pressure Relief Damper, UVGI Lamp, SITC of Medical Grage copper pipe line of 22 MM , SITC of Medical Grage copper pipe line of 15 MM , SITC of Medical gas outlet (Point of Use), Supply & Installation of 18G AL Risers, Spray Painted with dampers, flange type G-4 filter , openable panels, arrangement to clean filters for above systems and with 16G SS 304 perforated sheet with oppsite blade damper in the front.Risers must be easy to clean & accessible. Riser should be inner insulated with 6mm nitril rubber., Supply & application of indoor duct thermal insulation of 19mm thk XLPE/Nitril rubber on outdoor surface of duct with aluminium foil by using food grade adhesive., Supply & application of exposed duct thermal insulation of 19mm thk XLPE/Nitril rubber on outdoor surface of duct with UV protective using 5mil fiberglass cloth and applying two layers of LAC coating and food grade adhesive., Supply and fixing of duct acoustic insulation Class 1 open cell Nitrile rubber with non VOC type adhesive and accessories -15mm, Removing of existing fire sprinkler, smoke detector and terminate the line by holding water , Supply and Fixing of ABC 6 KG Extinguisher, Supply and Fixing of CO2 4.5 KG Extinguisher, Supply and Fixing Emergency Evaccuation plan of size 600X450 MM in (Sandwhich with 3 mm ACP & 10MM acralic sheet fixed by stud and screw)., Supply and laying of 2x1.5 Sq mm FRLS Armoured cable, Electrical Panel as per specification, AHU Motor Capacity 2.2 / 3.7 KW, VFD FOR 3.7 KW MOTOR, SITC of heater bank with single phase electrical strip heaters of 0.75 kW x 3 Nos. capacity with proper installtion arrangement. Along with Humidistat, safety thermostat & Air stat with necessary interlocking with HVAC panel., Electrical power cabling Copper armourred.4C X 4 Sqmm , Electrical power cabling Copper armourred.4C X 6.0 Sqmm , Electrical power cabling Copper armourred.4C X 10.0 Sqmm , Electrical power cabling Copper armourred.4C X 1.5 Cu shielded Cable, Supply Laying Testing and Commsiisoning of Electrical wire and conduit2X2.5 Sqmm X 1X1.5 Sqmm for earthing, Supply Laying Testing and Commsiisoning of Electrical wire and conduit 2X4 Sqmm X 1X2.5 Sqmm for earthing, Supply Laying Testing and Commsiisoning of 25 mm MS conduit , Supply Laying Testing and Commsiisoning of 32 mm PVC conduit, Supply Laying Testing and Commsiisoning of Earthing Strip with accessorie
|
Tender Detail : |
Supply of Air Handling Unit,su... |